To measure for blinds, record the opening’s width at the top, middle and bottom, its height at the left, center and right, and the usable mounting depth. Inside-mount blinds fit within that opening; outside-mount blinds cover it with additional overlap. Keep the measured opening size separate from the finished blind size.
Before choosing window blinds, decide whether the priority is visible trim, privacy or darkness. Then use the measuring instructions for the selected mechanism to choose the order readings and deductions. A roller, a slatted blind and a framed blackout shade do not necessarily use the same order size.
What to measure before ordering blinds
Use a steel tape measure, a pencil and a stable stepladder where needed. Label each window separately, even when several look identical. Keep the tape straight and level for width readings, and vertical for height readings.
Record width × height, in that order. Height is also called drop; recess depth is the separate front-to-back dimension. Measure the finished opening, not a drawing or an old order. The federal Window Blinds guide specification, UFGS 12 21 00, requires on-site dimensional checks before work proceeds.
Use the units requested on the order form: 120 cm is 1,200 mm, not 120 mm. NIST gives one inch as exactly 25.4 mm. Keep inch measurements as fractions rather than rounding to whole inches, and retain the original readings before any order-specific rounding.
| Measurement | Inside mount / recess fit | Outside mount / outside-recess fit |
|---|---|---|
| Width | Measure the opening at the top, middle and bottom. Select the reading required for the product; many blinds use the smallest, while some rollers use the top. | Measure the full span to cover, including the chosen side overlaps. Check whether the order width describes the hardware or the fabric. |
| Height / drop | Measure from the top inside surface to the sill at the left, center and right. The required reading varies by product. | Measure from the intended top of the blind to its finished lower edge, using the supplier’s stated reference points. |
| Mounting space | Check usable depth, bracket positions and obstructions. | Check flat mounting space and clearance over trim, handles and projecting sills. |
Should blinds go inside or outside the window frame?
Inside-mount blinds sit within the opening and leave the surrounding trim visible. They need enough depth for the fittings and an unobstructed path for the blind. The headrail is the housing for the mechanism at the top.
Outside-mount blinds attach to the surrounding wall or trim; “outside” means outside the recess, not outdoors. They can cover uneven edges and overlap a shallow opening. When combining window treatments, leave room for the blind and any curtain track to operate independently.
Top-fix brackets attach to a horizontal surface above the blind; face-fix brackets attach to a vertical surface. These terms describe the fixing surface, not whether the blind sits inside or outside the recess.
Check how the window type affects movement: turn the handle and open the sash before marking the brackets. The blind must clear both. Projecting trim may require compatible extension brackets or spacers, while the mounting surface must support the fittings securely.
How to measure for inside-mount blinds
1. Check recess depth: minimum mounting depth vs. flush fit
Measure the unobstructed front-to-back space at the bracket positions. Handles, locks and vents reduce usable depth; the distance to the glass alone can be misleading. Check the fabric, bottom rail and rotating slats along their full travel path.
Minimum mounting depth is the space needed to secure the brackets. Flush-mount depth is the space needed to keep the specified assembly behind the front edge of the opening. Confirm whether that assembly includes the valance or cassette cover. A secure inside mount can still project into the room.

Slat width does not determine mounting depth. Check the complete assembly drawing, including space to clip the blind into its brackets and reach any battery pack or charging connection.
2. Measure the width at three points
Measure between the inside faces of the opening, or side jambs, at the top, middle and bottom. Take the readings at the depth where the blind will run, not across a wider decorative edge at the front. Record all three.
Mark the smallest width, but keep the top reading too. A roller’s mechanism occupies a different part of the opening from its fabric, so an order may use the top width while still requiring the fabric and bottom bar to clear a narrower section below.
Do not average the three readings. For a partly tiled recess, also record the distance between the tile faces and check it against the moving parts.
3. Measure the height at three points
Measure vertically from the top inside surface to the sill at the left, center and right. With no sill, use the intended lower stopping point. For floor-length vertical custom blinds, measure to the finished floor before applying the specified floor clearance.
Keep all three heights. Use the longest or shortest only as directed for the selected blind; a floor-clearance requirement is different from covering the full opening.

Also allow for the raised stack: slats on a Venetian blind, folds on a Roman shade, or compressed cells on a honeycomb shade. These types of window shades occupy different amounts of glass when raised. Roller and zebra shades need room for the roll, any cassette and the bottom bar.
4. Apply the product’s rounding instructions
Rounding and fitting deductions are separate. Record the tape reading first, then round only in the direction and increment required by the order form.
For a form accepting 1/8-inch increments, a width of 36 1/16 inches becomes 36 inches under a round-down instruction. A height of 60 3/16 inches becomes 60 1/4 inches under a round-up instruction. Those directions are examples, not rules for every blind.
Blind-size deductions: recess size vs. exact size
Recess size means the window-opening measurement submitted before the supplier’s fitting deduction. Exact size or finished blind size means the requested product dimension as that supplier defines it. For a roller, that may be the full bracket-to-bracket width rather than the fabric width.
Do not subtract a clearance and then submit the reduced figure as a recess size unless the product instructions expressly require it. That can apply the allowance twice. Likewise, do not enlarge an inside-mount order to compensate for an anticipated fabric gap: the hardware may no longer fit.
A fitting deduction deliberately reduces the order dimension to provide clearance. A manufacturing tolerance describes permitted variation around the specified finished dimension. Neither changes the raw window measurement on your worksheet.
Inside-mount example: which numbers go in the order?
The federal UFGS 12 21 00 designer’s note allows 6 mm at each jamb for a typical horizontal-blind installation, with exceptions for some slats and window configurations. The following example uses that metric allowance to explain clearance; it is not a deduction to apply to every order.
| Reading | Recorded measurement |
|---|---|
| Width: top / middle / bottom | 1,204 / 1,198 / 1,201 mm |
| Height: left / center / right | 1,455 / 1,453 / 1,456 mm |
| Usable depth | 72 mm; suitability must be checked for the selected product |
Assume the chosen blind uses the smallest width and the factory applies 6 mm clearance per side. The recess width entered is 1,198 mm; the calculated finished width is 1,198 − 6 − 6 = 1,186 mm. Entering 1,186 mm as the recess width would apply the deduction twice.
That finished width leaves 12 mm of combined clearance at the narrowest point and 18 mm at the widest, before manufacturing variation. Alignment determines the gap on each side. Select the height separately from the three recorded readings, and check the 72 mm depth against the assembly drawing. UFGS does not establish a universal rule for which height to enter.
How to measure for outside-mount blinds
1. Mark the area the blind should cover
Decide whether the blind will cover the opening or the surrounding trim as well. Measure that base span at its widest point, then choose the extra overlap on each side. Mark the final left and right coverage edges with removable tape. If you measure directly between those final marks, do not add the overlaps again.
Required coverage width = base opening or trim span + left overlap + right overlap.
Choose the side overlaps from the required coverage and available wall space. Check both edges for handles, adjacent walls and other obstructions. A dimension suitable for privacy is not automatically enough for blackout, particularly when the fabric hangs well forward of the opening.
2. Set the top and bottom positions
Mark the top of the headrail and confirm enough flat surface for its brackets. Measure from the specified upper reference point to the desired lower edge. A projecting window sill may set that lower edge; handles and radiators may restrict a longer drop.
When calculating from opening height rather than measuring the endpoints directly:
Required coverage height = opening height + top extension + bottom extension.
For example, an opening 1,456 mm high with a chosen 70 mm top extension and 50 mm bottom extension gives 1,456 + 70 + 50 = 1,576 mm. These extensions are illustrative, not minimums. Enter this as the order drop only when the marked endpoints match the blind’s height definition.
Do not add the top and bottom allowances again after measuring between the final marked positions. That direct measurement already includes them.
Mounting a Roman shade higher can keep its raised folds above more of the glass, but increases the required drop. For vertical blinds, check the gathered vane stack and draw direction so they do not obstruct a doorway.
3. Check fabric coverage separately from hardware width
A roller shade’s fabric can be narrower than its complete mounting assembly. Confirm the bracket-to-bracket width, fabric width and offset at each end. Do not use a fixed allowance borrowed from another roller mechanism.

For a bracket-width order, the relevant calculation is:
Required overall width = required fabric width + the product’s confirmed total hardware-to-fabric difference.
For an illustrative 1,204 mm opening with a chosen fabric overlap of 50 mm on each side, the required fabric width is 1,304 mm. If the assembly drawing then shows a total hardware-to-fabric difference of 30 mm, the overall width is 1,334 mm. Both allowances are assumptions for this calculation; replace them with the selected system’s dimensions.
Also check the offset at each end. The control-side gap and opposite-side gap need not be equal, so centering the brackets may not center the fabric. Ask the supplier to confirm the resulting coverage before ordering a tight outside fit.
Measuring for blackout blinds
Opaque fabric does not stop light entering around its edges. Slatted blinds can also admit light between slats or through cord holes. An outside mount improves overlap, but does not by itself guarantee a dark room.
For a darker room, plan the perimeter as well as the fabric: side overlap, the gap above the roll or headrail, and the lower stopping point. A compatible system with side channels can control edge light while still mounting inside the recess.
UFGS 12 24 13 specifies a blackout assembly with a head box and light-trapping side and sill channels. Measure room for the complete frame and bottom seal, including access to service the roller, rather than sizing it as a bare blind.
For an outer curtain layer, measure blackout curtains from their own rod or track, not from the blind’s dimensions. Allow the curtain fabric to pass in front of the blind without catching its controls or bottom rail.
Ready-made blinds, replacement blinds and unusual windows
Ready-made or cut-to-width blinds
Check whether the listed width is a nominal size or the actual finished width. Compare the stated finished dimensions with the measured opening, including the clearance required for operation. Do not assume a fixed half-inch reduction is already included.
For a cut-to-width blind, give the cutting service the opening dimensions and mount type, then confirm who applies the clearance. Check the permitted trimming range and whether the drop can be shortened. Cordless and motorized mechanisms may restrict either adjustment.
Uneven openings and partly tiled recesses
Keep all six width and height readings. Check the head for level and the jambs for vertical alignment, then measure both diagonals if the opening looks skewed. A diagonal comparison alone does not prove the blind will run freely: an opening can keep the same width while shifting sideways from top to bottom.
If an opening widens by 15 mm from its narrowest to its widest point, a constant-width blind has 15 mm more combined side space at the wider cross-section. How that space divides between the sides depends on alignment. An outside mount may hide the uneven edges more effectively.
For partly tiled openings, check the upper width and the width between the finished tile faces. Pressure-mounted blinds also need suitable contact surfaces. Finish any window maintenance or trim repairs that change the opening before taking the final readings.
Bay windows and two blinds in one opening
In a bay window, adjoining headrails and brackets can collide at the corners. Mark their actual mounting positions and use full-size card profiles to check the meeting points and handle clearances. Measure between those points, not across the glass alone.
For two blinds in one opening, record the overall width and intended dividing point. Confirm the center clearance for either a shared headrail or two independent units before splitting the order widths.
Doors, no-drill frames and roof windows
For a door-mounted blind, check the handle, hinges, door swing and any required bottom hold-down brackets. For floor-length verticals, confirm whether the order drop includes the headrail and who provides the floor clearance. Do not subtract the headrail height from an overall-drop order.
Clip-in framed blinds may require visible-glass measurements, glazing-bead compatibility and frame-depth checks. Tension-fit blinds use a different mounting method. Neither should be ordered from ordinary recess measurements without confirming the fitting requirements.
For roof-window blinds, record the window model and size code when the fitting system requires them. Check the frame profile and guide-rail arrangement as well as the glass dimensions. Matching the glass width alone does not establish that the blind will fit.
Replacing an existing blind
When replacing an existing fitting with custom blinds, remeasure the finished opening. New brackets or controls can change the required depth even when the blind type stays the same. Use the old blind’s dimensions only for a confirmed like-for-like replacement, recording the complete assembly and fabric width separately.
Blind-measuring worksheet: raw readings and final order size
Use one record per window, keeping raw readings separate from the final order.
| Field | Your measurement or selection |
|---|---|
| Room and window label | ______________________________ |
| Blind type, assembly reference and control system | ______________________________ |
| Inside or outside mount; order-size definition | ______________________________ |
| Units | ______________________________ |
| Width: top / middle / bottom | __________ / __________ / __________ |
| Height: left / center / right | __________ / __________ / __________ |
| Usable depth and flat bracket-mounting space | ______________________________ |
| Product’s minimum depth / flush-mount depth | __________ / __________ |
| Handles, trim, tiles, sill or floor restrictions | ______________________________ |
| Outside overlap and fabric-width allowance, if applicable | ______________________________ |
| Final order: width × height | __________ × __________ |
| Deductions made by supplier / made by customer | ______________________________ |
Before ordering, confirm width × height, mount type, control side and responsibility for each deduction. BS EN 13120 addresses internal-blind performance and safety; it is not a universal table of ordering allowances.
Where young children may be present, choose cordless blinds, as the U.S. Consumer Product Safety Commission advises. Check the mounting requirements for that control system.
Frequently asked questions
Do you measure the glass or the window frame for blinds?
For ordinary inside mounts, measure the opening where the blind will fit. Outside mounts use the area to cover. Clip-in framed systems may instead require visible-glass measurements and window-profile checks.
How deep does a window need to be for inside-mount blinds?
Use the minimum mounting depth specified for the complete blind and control system. A flush installation also needs room for the headrail, cassette and any included valance behind the opening’s front edge. There is no single minimum depth for every blind.
What size blind should I order for a 120 cm recess?
Enter 120 cm, or 1,200 mm, on a recess-size order only when that is the width reading the instructions request. Leave the stated factory deduction to the factory. An exact-size order instead needs the finished assembly width after the required clearance has been established.
Should I deduct half an inch when ordering blinds?
No automatic half-inch deduction applies. A recess-size order may already include a factory allowance, and a stocked blind may have a nominal size different from its actual width. Subtract clearance yourself only when the ordering instructions require it.
How much wider should outside-mount blinds be than the window?
Add the chosen side overlaps to the base opening or trim span. Do not add them again if you measured between the final coverage edges. For rollers, check fabric coverage separately from hardware width; there is no universal addition.
Can an inside-mount blind block out light?
Ordinary inside mounts leave perimeter gaps. Compatible side channels or a fitted blackout frame can control edge light, subject to the system’s depth and installation requirements.
Resources
- U.S. Army Corps of Engineers, NAVFAC and AFCEC — “UFGS 12 21 00: Window Blinds,” sections 2.1.1, 3.1 and 3.3.
- U.S. Army Corps of Engineers, NAVFAC and AFCEC — “UFGS 12 24 13: Roller Window Shades,” section 2.1.2.8.
- National Institute of Standards and Technology — “SI Units – Length.”
- British Standards Institution — “BS EN 13120:2009+A1:2014: Internal blinds. Performance requirements including safety.”
- U.S. Consumer Product Safety Commission — “The Safest Window Coverings When Young Children Are Present Are Cordless.”
- Architecture Lab — How to Make Blackout Curtains; How to Combine Sheer and Blackout Curtains; Do Blackout Curtains Keep Heat Out.
