The roller and curtain occupy separate paths at the window head.
A concealed blind is part of the window-head detail. The visible slot may be narrow, but the ceiling above it must hold the roller, brackets and drive, with room to remove them later. A curtain adds another moving layer: its track, gathered fabric and open stack all occupy space beyond the line shown on an elevation.
The pocket and motor positions belong on the ceiling, joinery and electrical drawings before the ceiling is closed. Once light control, privacy and the type of blind are settled, the drawings can establish where the hardware fits, how it moves and how it is maintained.
The blind pocket in section
The pocket must accommodate the blind when it is fully raised. Its depth depends on the roller or headrail; its length includes brackets and end hardware. The fabric also needs a clear path past window handles and opening sashes. Drawing the fully raised position makes those clearances visible. With tilt-and-turn windows, check the headrail and fabric against both the inward swing and the tilted sash; handle clearance alone is not enough.
A concealed-blind installation guide gives typical box sizes of 100 × 100 mm for roller blinds up to 2.4 m wide and 130 × 130 mm for blinds up to 3.5 m wide. Those dimensions illustrate the space a system may need; the selected assembly determines the pocket shown on the construction drawing.
The opening below the pocket serves a second purpose: access. A removable closure needs room to come out, and the roller or motor needs a route out after it. A detail that hides the equipment but traps it above the finished ceiling leaves maintenance unresolved.

With a roller behind a curtain, the two layers need separate operating paths. The section establishes their spacing; the reflected ceiling plan reveals conflicts with lights, sprinklers and ventilation. The final order should use the built opening and the selected product’s measurement and deduction rules.
Curved tracks and curtain stack-back
A bay-window track follows the room in plan, but its bends are limited by the profile and running components. The curtain heading matters too: a track may accept a curve that the chosen fabric arrangement cannot negotiate cleanly.
One electric-track technical catalogue lists a bending radius greater than 250 mm for its standard profile. Its recessed profile is listed at 500–750 mm, with larger radii on request. These figures belong to those specific profiles. Changing from a standard to a recessed track can therefore change the curve built into the ceiling.
The open curtain needs equal attention. Gathered fabric occupies track length, called stack-back, as well as depth in front of the glass. Extending a track beyond the opening can move that stack onto the adjacent wall. Where the wall is short, some glass remains covered even with the curtain fully open.

Fullness describes the amount of fabric relative to the covered width. It does not establish the open stack size. Heading, lining and carriers also affect how tightly the curtain gathers. In the same linked catalogue, specified heading components use stack allowances of 210 or 260 mm per metre, plus 190 mm for each curtain stack. Those are examples for the documented components; another heading needs its own calculation.
Plan and elevation should show both the closed curtain and its open stack. That makes a blocked door, crowded corner or loss of clear glazing visible before ordering. Curtain width and finished drop can then be resolved around the selected hardware.
Support and power above the ceiling
The ceiling finish conceals the fixing; it does not establish its capacity. The support must carry the track, fabric, lining and motor through brackets into a suitable substrate. A manufacturer’s track-load rating says little about the strength of a particular fixing in plasterboard.
The detail should identify the backing or structural support, fixing positions and specified fasteners. The curtain supplier and ceiling contractor should inspect the support before it is covered. Record its position so later bracket fixings reach the backing.
Power has its own spatial requirements. A wired motor needs the correct supply and a cable at the drive end. Battery operation avoids some wiring but leaves a charging or replacement task. Radio control describes how a command reaches the blind, not how the motor receives power.
Using the same window identifier on the electrical plan and treatment schedule helps keep the motor position consistent. The control arrangement should also establish what happens after a power failure and whether manual operation is available. The drawing must leave room to reach the drive end after installation.
Fabric, daylight and heat
A fabric sample shows texture and color. Its technical data explains how much light passes through it and how it behaves in sunlight. Solar-screen openness is the proportion of gaps in the weave; it is not interchangeable with visible transmittance or solar heat gain.
A solar-screen technical card lists optical properties by fabric color. The specification therefore needs the selected fabric and color, with the glazing and installation position considered alongside them. An openness percentage alone leaves part of the daylight decision unresolved.
Blackout requires attention to the perimeter. Opaque cloth can still leave light at the head, sill, sides or meeting edges. The acceptable result differs between a bedroom and a photographic darkroom. Overlaps, channels and the method of assessing darkness should follow that use.
The Cool Climate and Warm Climate ratings allow comparisons across certified window coverings. “Max Improvement” is a benchmark within a category, not a percentage saving. A curtain layer raises the related question of heat control at the window.
For new residential buildings in England, Approved Document O says internal blinds and curtains should not be counted toward meeting overheating requirement O1. A treatment may help occupants without serving as the building’s compliance strategy.
Fire performance and cord safety
Where fire performance is required, the specification needs a report for the fabric-and-lining construction. The relevant textile fire-test standard distinguishes test methods and assemblies; “fire-retardant” alone does not identify what was tested.
Cord layout adds a safety requirement. Consumer safety guidance recommends cordless coverings where young children are present, because accessible cords pose a strangulation hazard. Specify the operating arrangement with the blind and check its safety provisions after installation.
Installation order and final checks
A recessed system links curtain installation to the ceiling programme. One recessed-track installation guide starts with blocking and a 32 mm drywall recess. The pocket is then installed and measured before the track is ordered; finishing precedes final track installation. That sequence and dimension apply to the illustrated system, not every recessed track.
Ordering the track after measuring the installed pocket lets its width follow the built opening. A system substitution may still change the recess, support or cable position after those elements have been built.
For each opening, the schedule records the selected assembly, fabric, drawing reference, support, power and responsibility for site measurement. The supplier drawing and revision connect those entries to the actual assembly.
At handover, the treatment should run through its full travel with adjacent windows and doors in use. Controls, limits and service access should be demonstrated, including how the concealed motor can be reached for maintenance.
Resources
- Concealed blind-pocket dimension guide.
- Electric curtain-track geometry and stack-back catalogue.
- Recessed curtain-track installation instructions.
- Solar-screen optical-properties card.
- Residential window-covering energy-rating guide.
- Overheating guidance for new residential buildings in England.
- Textile fire-test standard and window-covering cord safety guidance.